device library

ABB TRIO-20.0/27.6-TL-OUTD string inverter

Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.

coherence-checked

Round-trips through a real Modbus stack with no overlapping addresses and a word-order-sensitive codec — the map is internally coherent and wire-decodable. Does NOT prove byte-order or scaling match a real device: the emulator is seeded from the map's own types, so a uniformly wrong byte-order still round-trips. Only hardware-verified confirms byte-order/scale on the wire.

pointaddress (0-based)typescaleunit
Inverter – Start register100U161
Inverter – Map size101U161
Inverter – Map Version102U161
Inverter address103U161
Inverter – Serial number (SN0)104U161
Inverter – Serial number (SN1)105U161
Inverter – Serial number (SN2)106U161
Inverter – Serial number (SN3)107U161
Inverter – Serial number (SN4)108U161
Inverter – Serial number (SN5)109U161
Inverter – Part number (PN0)110U161
Inverter – Part number (PN1)111U161
Inverter – Part number (PN2)112U161
Inverter – Part number (PN3)113U161
Inverter – Part number (PN4)114U161
Inverter – Part number (PN5)115U161
Inverter – Model identifier116U161
Inverter – Country/Grid standard117U161
Inverter – Transformer type118U161
Inverter - Week production - High byte119U161
Inverter - Week production - Low byte120U161
Inverter - Year production - High byte121U161
Inverter - Year production - Low byte122U161
Inverter - States (Byte 0) - Global state123U161
Inverter - States (Byte 1) - Inverter state124U161
Inverter - States (Byte 2) - DC/DC Channel 1 state125U161
Inverter - States (Byte 3) - DC/DC Channel 2 state126U161
Inverter - States (Byte 4) - Alarm state127U161
Display Board - Presence128U161
Communication Board - Presence129U161
Fuse Control Board - Presence130U161
Inverter - Daily Energy131F32BE1Wh
Inverter - Total Energy133F32BE1kWh
Inverter - Partial Energy135F32BE1kWh
Inverter - Week Energy137F32BE1kWh
Inverter - Monthly Energy139F32BE1kWh
Inverter - Yearly Energy141F32BE1kWh
Inverter - Grid Voltage143F32BE1V
Inverter - Grid Current145F32BE1A
Inverter - Grid Power147F32BE1W
Inverter - Frequency149F32BE1Hz
Inverter - Input 1 Power151F32BE1W
Inverter - Input 1 Voltage153F32BE1V
Inverter - Input 1 Current155F32BE1A
Inverter - Input 2 Power157F32BE1W
Inverter - Input 2 Voltage159F32BE1V
Inverter - Input 2 Current161F32BE1A
Inverter - Inverter Temperature163F32BE1°C
Inverter - Booster Temperature165F32BE1°C
Inverter - Isolation Resistance167F32BE1MΩ
Inverter - Wind Generator Frequency169F32BE1Hz
Inverter - Cos(φ)171F32BE1
Inverter - Presence173U161
Remote on/off180U161
Reset by-hand181U161
Permanent and dynamic mode - Power ramping interval190U161
Dynamic mode – Timeout191U161min
Set transient options198U161
Dynamic Mode – Reactive Power management by fixed PF200F32BE1
Permanent Mode – Reactive Power management by fixed PF202F32BE1
Permanent Mode – Reset PF to 1205U161
Dynamic Mode – Active Power management210U161%
Permanent Mode – Active Power management212U161%
Permanent Mode – Reset Active Power to 100% of Nominal Power215U161
Dynamic Mode – Reactive power management; set fixed Q by conventional PF220F32BE1
Permanent Mode – Reactive power management; set fixed Q by conventional PF222F32BE1
Dynamic Mode – Reactive Power management; set fixed Q by percentage225I161%
Permanent Mode – Reactive Power management; set fixed Q by percentage227I161%
Auxiliary Boards – Start register250U161
Auxiliary Board – Map size251U161
Auxiliary Board – Map Version252U161
Inverter – Serial number (SN0)254U161
Inverter – Serial number (SN1)255U161
Inverter – Serial number (SN2)256U161
Inverter – Serial number (SN3)257U161
Inverter – Serial number (SN4)258U161
Inverter – Serial number (SN5)259U161
Communication Board – Serial number (SN0)276U161
Communication Board – Serial number (SN1)277U161
Communication Board – Serial number (SN2)278U161
Communication Board – Serial number (SN3)279U161
Communication Board – Serial number (SN4)280U161
Communication Board – Serial number (SN5)281U161
Communication Board – Part number (PN0)282U161
Communication Board – Part number (PN1)283U161
Communication Board – Part number (PN2)284U161
Communication Board – Part number (PN3)285U161
Communication Board – Part number (PN4)286U161
Communication Board – Part number (PN5)287U161
Communication Board – Week production – High byte288U161
Communication Board – Week production – Low byte289U161
Communication Board – Year production – High byte290U161
Communication Board – Year production – Low byte291U161
Fuse Control Board – Serial number (SN0)292U161
Fuse Control Board – Serial number (SN1)293U161
Fuse Control Board – Serial number (SN2)294U161
Fuse Control Board – Serial number (SN3)295U161
Fuse Control Board - Serial number (SN5)296U161
Fuse Control Board - Part number (PN0)297U161
Transient options configurable298U161
Fuse Control Board - Part number (PN1)298U161
Heartbeat counter299U161
Fuse Control Board - Part number (PN2)299U161
Inverter - Grid Reactive Power300F32BE1VAR
Fuse Control Board - Part number (PN3)300U161
Fuse Control Board - Part number (PN4)301U161
Inverter - Grid Voltage302F32BE1V
Fuse Control Board - Part number (PN5)302U161
Fuse Control Board - Week production - High byte303U161
Inverter - Grid Power304F32BE1W
Fuse Control Board - Week production - Low byte304U161
Fuse Control Board - Year production - High byte305U161
Inverter - Grid Current306F32BE1A
Fuse Control Board - Year production - Low byte306U161
Communication Board - States (Byte 4)307U161
Communication Board - States (Byte 5)308U161
Fuse Control Board - States (Byte 0)309U161
Fuse Control Board - States (Byte 1)310U161
Fuse Control Board – States (Byte 1)311U161
Fuse Control Board – States (Byte 2)312U161
Fuse Control Board – States (Byte 3)313U161
Fuse Control Board – States (Byte 4)314U161
Communication Board – PT100315F32BE1°C
Communication Board – PT1000317F32BE1°C
Communication Board – Analog Input 1319F32BE1V OR mA
Communication Board – Analog Input 2321F32BE1V OR mA
Communication Board – NTC323F32BE1°C
Fuse Control Board – Voltage 1A325F32BE1V
Fuse Control Board – Voltage 1B327F32BE1V
Fuse Control Board – Voltage 1C329F32BE1V
Fuse Control Board – Voltage 1D331F32BE1V
Fuse Control Board – Voltage 1E333F32BE1V
Fuse Control Board – Voltage 2A335F32BE1V
Fuse Control Board – Voltage 2B337F32BE1V
Fuse Control Board – Voltage 2C339F32BE1V
Fuse Control Board – Voltage 2D341F32BE1V
Fuse Control Board – Voltage 2E343F32BE1V
Fuse Control Board – Voltage Ch1345F32BE1V
Fuse Control Board – Voltage Ch2347F32BE1V
Fuse Control Board – Current 1A349F32BE1A
Fuse Control Board – Current 1B351F32BE1A
Fuse Control Board – Current 1C353F32BE1A
Fuse Control Board – Current 1D355F32BE1A
Fuse Control Board – Current 1E357F32BE1A
Fuse Control Board – Current 2A359F32BE1A
Fuse Control Board – Current 2B361F32BE1A
Fuse Control Board – Current 2C363F32BE1A
Fuse Control Board – Current 2D365F32BE1A
Fuse Control Board – Current 2E367F32BE1A
Fuse Control Board – States (Byte 5)369U161
Set unit of registers 0507, 0508, 0511 and 0512501U161
Set active mode (permanent or dynamic)502U161
Permanent and dynamic mode – Power ramping interval503U161
Dynamic mode – Timeout504U161min
Set transient options505U161
Set reactive power control mode506U161
Dynamic Mode – Reactive Power management; set fixed Q by percentage507I161% OR ‰
Dynamic Mode – Active Power management; set Active Power expressed as percentage508U161% OR ‰
Dynamic Mode – Reactive Power management by fixed PF509F32BE1
Permanent Mode – Reactive Power management; set fixed Q by percentage511I161% OR ‰
Permanent Mode – Active Power management; set Active Power expressed as percentage512U161% OR ‰
Permanent Mode – Reactive Power management by fixed PF513F32BE1
Reset Active Power management515U161
Reset Reactive Power management516U161
Registers Map – Type3650U161
Registers Map – Inverter family supported3651U161
Registers Map – Major Version3652U161
Registers Map – Minor Version3653U161

link settings as documented (unverified): RTU; default 19200 8N1; FC 03,04,06,16; Interface: RS-485 (half duplex). Start bit: 1, Stop bit: 1, Parity: No parity, Data bits: 8. Default baud rate is 9600 on USA and Japan versions, and 19200 on Europe versions.

bench facts as documented (unverified)
terminalsRS-485 serial line
broadcastsupported
model register115
serial register103
identification notesModel identifier register is 115 (0-based). Serial number registers are 103 to 108 (0-based).
doc revision1.6
firmware applicabilityMinimum Inverter Update Version: 1542C for Europe version; 1542D for USA and Japan version
field reports — community-sourced, unverified (checked 2026-06-11)
  • The inverter uses Word Swapped Floating Point 32-bit (SF32) data types where the two Modbus registers must be swapped before processing the IEEE754 floating point value. [source]
  • When the inverter enters standby/night mode due to low solar input voltage, Modbus RTU communication may be suspended or respond with errors, causing communication timeouts on the PLC/master side. [source]
  • Modbus data registers are documented as 1-based addresses in some vendor materials, requiring an offset of -1 (0-based addressing) in the Modbus PDU request (e.g., register 301 is requested as 0x012C / 300). [source]
  • confirmed: Baud rates [2400, 4800, 9600, 19200, 38400, 57600, 115200] with default 19200 on Europe versions and 9600 on USA/Japan versions — confirmed by Modbus RTU Register Map For TRIO-20.0 (27.6) - TL-OUTD Revision 1.6
  • confirmed: Minimum Inverter Update Version: 1542C for Europe version; 1542D for USA and Japan version — confirmed by Modbus RTU Register Map For TRIO-20.0 (27.6) - TL-OUTD Revision 1.6
  • confirmed: Model identifier register is 115 and serial number registers are 103 to 108 (0-based) — confirmed by Modbus RTU Register Map For TRIO-20.0 (27.6) - TL-OUTD Revision 1.6
  • confirmed: Broadcast mode is supported for write single (06) and write multiple (16) registers — confirmed by Modbus RTU Register Map For TRIO-20.0 (27.6) - TL-OUTD Revision 1.6

The trust ladder

Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.

Device not here? Upload its manual and get a checked map back. It's free.

Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.

Building on a lot of devices? License the library — machine-readable maps, the firmware matrix, and API access.