Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.
Round-trips through a real Modbus stack with no overlapping addresses and a word-order-sensitive codec — the map is internally coherent and wire-decodable. Does NOT prove byte-order or scaling match a real device: the emulator is seeded from the map's own types, so a uniformly wrong byte-order still round-trips. Only hardware-verified confirms byte-order/scale on the wire.
| point | address (0-based) | type | scale | unit |
|---|---|---|---|---|
| Inverter – Start register | 100 | U16 | 1 | |
| Inverter – Map size | 101 | U16 | 1 | |
| Inverter – Map Version | 102 | U16 | 1 | |
| Inverter address | 103 | U16 | 1 | |
| Inverter – Serial number (SN0) | 104 | U16 | 1 | |
| Inverter – Serial number (SN1) | 105 | U16 | 1 | |
| Inverter – Serial number (SN2) | 106 | U16 | 1 | |
| Inverter – Serial number (SN3) | 107 | U16 | 1 | |
| Inverter – Serial number (SN4) | 108 | U16 | 1 | |
| Inverter – Serial number (SN5) | 109 | U16 | 1 | |
| Inverter – Part number (PN0) | 110 | U16 | 1 | |
| Inverter – Part number (PN1) | 111 | U16 | 1 | |
| Inverter – Part number (PN2) | 112 | U16 | 1 | |
| Inverter – Part number (PN3) | 113 | U16 | 1 | |
| Inverter – Part number (PN4) | 114 | U16 | 1 | |
| Inverter – Part number (PN5) | 115 | U16 | 1 | |
| Inverter – Model identifier | 116 | U16 | 1 | |
| Inverter – Country/Grid standard | 117 | U16 | 1 | |
| Inverter – Transformer type | 118 | U16 | 1 | |
| Inverter - Week production - High byte | 119 | U16 | 1 | |
| Inverter - Week production - Low byte | 120 | U16 | 1 | |
| Inverter - Year production - High byte | 121 | U16 | 1 | |
| Inverter - Year production - Low byte | 122 | U16 | 1 | |
| Inverter - States (Byte 0) - Global state | 123 | U16 | 1 | |
| Inverter - States (Byte 1) - Inverter state | 124 | U16 | 1 | |
| Inverter - States (Byte 2) - DC/DC Channel 1 state | 125 | U16 | 1 | |
| Inverter - States (Byte 3) - DC/DC Channel 2 state | 126 | U16 | 1 | |
| Inverter - States (Byte 4) - Alarm state | 127 | U16 | 1 | |
| Display Board - Presence | 128 | U16 | 1 | |
| Communication Board - Presence | 129 | U16 | 1 | |
| Fuse Control Board - Presence | 130 | U16 | 1 | |
| Inverter - Daily Energy | 131 | F32BE | 1 | Wh |
| Inverter - Total Energy | 133 | F32BE | 1 | kWh |
| Inverter - Partial Energy | 135 | F32BE | 1 | kWh |
| Inverter - Week Energy | 137 | F32BE | 1 | kWh |
| Inverter - Monthly Energy | 139 | F32BE | 1 | kWh |
| Inverter - Yearly Energy | 141 | F32BE | 1 | kWh |
| Inverter - Grid Voltage | 143 | F32BE | 1 | V |
| Inverter - Grid Current | 145 | F32BE | 1 | A |
| Inverter - Grid Power | 147 | F32BE | 1 | W |
| Inverter - Frequency | 149 | F32BE | 1 | Hz |
| Inverter - Input 1 Power | 151 | F32BE | 1 | W |
| Inverter - Input 1 Voltage | 153 | F32BE | 1 | V |
| Inverter - Input 1 Current | 155 | F32BE | 1 | A |
| Inverter - Input 2 Power | 157 | F32BE | 1 | W |
| Inverter - Input 2 Voltage | 159 | F32BE | 1 | V |
| Inverter - Input 2 Current | 161 | F32BE | 1 | A |
| Inverter - Inverter Temperature | 163 | F32BE | 1 | °C |
| Inverter - Booster Temperature | 165 | F32BE | 1 | °C |
| Inverter - Isolation Resistance | 167 | F32BE | 1 | MΩ |
| Inverter - Wind Generator Frequency | 169 | F32BE | 1 | Hz |
| Inverter - Cos(φ) | 171 | F32BE | 1 | |
| Inverter - Presence | 173 | U16 | 1 | |
| Remote on/off | 180 | U16 | 1 | |
| Reset by-hand | 181 | U16 | 1 | |
| Permanent and dynamic mode - Power ramping interval | 190 | U16 | 1 | |
| Dynamic mode – Timeout | 191 | U16 | 1 | min |
| Set transient options | 198 | U16 | 1 | |
| Dynamic Mode – Reactive Power management by fixed PF | 200 | F32BE | 1 | |
| Permanent Mode – Reactive Power management by fixed PF | 202 | F32BE | 1 | |
| Permanent Mode – Reset PF to 1 | 205 | U16 | 1 | |
| Dynamic Mode – Active Power management | 210 | U16 | 1 | % |
| Permanent Mode – Active Power management | 212 | U16 | 1 | % |
| Permanent Mode – Reset Active Power to 100% of Nominal Power | 215 | U16 | 1 | |
| Dynamic Mode – Reactive power management; set fixed Q by conventional PF | 220 | F32BE | 1 | |
| Permanent Mode – Reactive power management; set fixed Q by conventional PF | 222 | F32BE | 1 | |
| Dynamic Mode – Reactive Power management; set fixed Q by percentage | 225 | I16 | 1 | % |
| Permanent Mode – Reactive Power management; set fixed Q by percentage | 227 | I16 | 1 | % |
| Auxiliary Boards – Start register | 250 | U16 | 1 | |
| Auxiliary Board – Map size | 251 | U16 | 1 | |
| Auxiliary Board – Map Version | 252 | U16 | 1 | |
| Inverter – Serial number (SN0) | 254 | U16 | 1 | |
| Inverter – Serial number (SN1) | 255 | U16 | 1 | |
| Inverter – Serial number (SN2) | 256 | U16 | 1 | |
| Inverter – Serial number (SN3) | 257 | U16 | 1 | |
| Inverter – Serial number (SN4) | 258 | U16 | 1 | |
| Inverter – Serial number (SN5) | 259 | U16 | 1 | |
| Communication Board – Serial number (SN0) | 276 | U16 | 1 | |
| Communication Board – Serial number (SN1) | 277 | U16 | 1 | |
| Communication Board – Serial number (SN2) | 278 | U16 | 1 | |
| Communication Board – Serial number (SN3) | 279 | U16 | 1 | |
| Communication Board – Serial number (SN4) | 280 | U16 | 1 | |
| Communication Board – Serial number (SN5) | 281 | U16 | 1 | |
| Communication Board – Part number (PN0) | 282 | U16 | 1 | |
| Communication Board – Part number (PN1) | 283 | U16 | 1 | |
| Communication Board – Part number (PN2) | 284 | U16 | 1 | |
| Communication Board – Part number (PN3) | 285 | U16 | 1 | |
| Communication Board – Part number (PN4) | 286 | U16 | 1 | |
| Communication Board – Part number (PN5) | 287 | U16 | 1 | |
| Communication Board – Week production – High byte | 288 | U16 | 1 | |
| Communication Board – Week production – Low byte | 289 | U16 | 1 | |
| Communication Board – Year production – High byte | 290 | U16 | 1 | |
| Communication Board – Year production – Low byte | 291 | U16 | 1 | |
| Fuse Control Board – Serial number (SN0) | 292 | U16 | 1 | |
| Fuse Control Board – Serial number (SN1) | 293 | U16 | 1 | |
| Fuse Control Board – Serial number (SN2) | 294 | U16 | 1 | |
| Fuse Control Board – Serial number (SN3) | 295 | U16 | 1 | |
| Fuse Control Board - Serial number (SN5) | 296 | U16 | 1 | |
| Fuse Control Board - Part number (PN0) | 297 | U16 | 1 | |
| Transient options configurable | 298 | U16 | 1 | |
| Fuse Control Board - Part number (PN1) | 298 | U16 | 1 | |
| Heartbeat counter | 299 | U16 | 1 | |
| Fuse Control Board - Part number (PN2) | 299 | U16 | 1 | |
| Inverter - Grid Reactive Power | 300 | F32BE | 1 | VAR |
| Fuse Control Board - Part number (PN3) | 300 | U16 | 1 | |
| Fuse Control Board - Part number (PN4) | 301 | U16 | 1 | |
| Inverter - Grid Voltage | 302 | F32BE | 1 | V |
| Fuse Control Board - Part number (PN5) | 302 | U16 | 1 | |
| Fuse Control Board - Week production - High byte | 303 | U16 | 1 | |
| Inverter - Grid Power | 304 | F32BE | 1 | W |
| Fuse Control Board - Week production - Low byte | 304 | U16 | 1 | |
| Fuse Control Board - Year production - High byte | 305 | U16 | 1 | |
| Inverter - Grid Current | 306 | F32BE | 1 | A |
| Fuse Control Board - Year production - Low byte | 306 | U16 | 1 | |
| Communication Board - States (Byte 4) | 307 | U16 | 1 | |
| Communication Board - States (Byte 5) | 308 | U16 | 1 | |
| Fuse Control Board - States (Byte 0) | 309 | U16 | 1 | |
| Fuse Control Board - States (Byte 1) | 310 | U16 | 1 | |
| Fuse Control Board – States (Byte 1) | 311 | U16 | 1 | |
| Fuse Control Board – States (Byte 2) | 312 | U16 | 1 | |
| Fuse Control Board – States (Byte 3) | 313 | U16 | 1 | |
| Fuse Control Board – States (Byte 4) | 314 | U16 | 1 | |
| Communication Board – PT100 | 315 | F32BE | 1 | °C |
| Communication Board – PT1000 | 317 | F32BE | 1 | °C |
| Communication Board – Analog Input 1 | 319 | F32BE | 1 | V OR mA |
| Communication Board – Analog Input 2 | 321 | F32BE | 1 | V OR mA |
| Communication Board – NTC | 323 | F32BE | 1 | °C |
| Fuse Control Board – Voltage 1A | 325 | F32BE | 1 | V |
| Fuse Control Board – Voltage 1B | 327 | F32BE | 1 | V |
| Fuse Control Board – Voltage 1C | 329 | F32BE | 1 | V |
| Fuse Control Board – Voltage 1D | 331 | F32BE | 1 | V |
| Fuse Control Board – Voltage 1E | 333 | F32BE | 1 | V |
| Fuse Control Board – Voltage 2A | 335 | F32BE | 1 | V |
| Fuse Control Board – Voltage 2B | 337 | F32BE | 1 | V |
| Fuse Control Board – Voltage 2C | 339 | F32BE | 1 | V |
| Fuse Control Board – Voltage 2D | 341 | F32BE | 1 | V |
| Fuse Control Board – Voltage 2E | 343 | F32BE | 1 | V |
| Fuse Control Board – Voltage Ch1 | 345 | F32BE | 1 | V |
| Fuse Control Board – Voltage Ch2 | 347 | F32BE | 1 | V |
| Fuse Control Board – Current 1A | 349 | F32BE | 1 | A |
| Fuse Control Board – Current 1B | 351 | F32BE | 1 | A |
| Fuse Control Board – Current 1C | 353 | F32BE | 1 | A |
| Fuse Control Board – Current 1D | 355 | F32BE | 1 | A |
| Fuse Control Board – Current 1E | 357 | F32BE | 1 | A |
| Fuse Control Board – Current 2A | 359 | F32BE | 1 | A |
| Fuse Control Board – Current 2B | 361 | F32BE | 1 | A |
| Fuse Control Board – Current 2C | 363 | F32BE | 1 | A |
| Fuse Control Board – Current 2D | 365 | F32BE | 1 | A |
| Fuse Control Board – Current 2E | 367 | F32BE | 1 | A |
| Fuse Control Board – States (Byte 5) | 369 | U16 | 1 | |
| Set unit of registers 0507, 0508, 0511 and 0512 | 501 | U16 | 1 | |
| Set active mode (permanent or dynamic) | 502 | U16 | 1 | |
| Permanent and dynamic mode – Power ramping interval | 503 | U16 | 1 | |
| Dynamic mode – Timeout | 504 | U16 | 1 | min |
| Set transient options | 505 | U16 | 1 | |
| Set reactive power control mode | 506 | U16 | 1 | |
| Dynamic Mode – Reactive Power management; set fixed Q by percentage | 507 | I16 | 1 | % OR ‰ |
| Dynamic Mode – Active Power management; set Active Power expressed as percentage | 508 | U16 | 1 | % OR ‰ |
| Dynamic Mode – Reactive Power management by fixed PF | 509 | F32BE | 1 | |
| Permanent Mode – Reactive Power management; set fixed Q by percentage | 511 | I16 | 1 | % OR ‰ |
| Permanent Mode – Active Power management; set Active Power expressed as percentage | 512 | U16 | 1 | % OR ‰ |
| Permanent Mode – Reactive Power management by fixed PF | 513 | F32BE | 1 | |
| Reset Active Power management | 515 | U16 | 1 | |
| Reset Reactive Power management | 516 | U16 | 1 | |
| Registers Map – Type | 3650 | U16 | 1 | |
| Registers Map – Inverter family supported | 3651 | U16 | 1 | |
| Registers Map – Major Version | 3652 | U16 | 1 | |
| Registers Map – Minor Version | 3653 | U16 | 1 |
| terminals | RS-485 serial line |
| broadcast | supported |
| model register | 115 |
| serial register | 103 |
| identification notes | Model identifier register is 115 (0-based). Serial number registers are 103 to 108 (0-based). |
| doc revision | 1.6 |
| firmware applicability | Minimum Inverter Update Version: 1542C for Europe version; 1542D for USA and Japan version |
Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.
Device not here? Upload its manual and get a checked map back. It's free.
Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.
Building on a lot of devices? License the library — machine-readable maps, the firmware matrix, and API access.