device library

Amperfied connect.home/connect.business wallbox (Modbus TCP)

Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.

coherence-checked

Round-trips through a real Modbus stack with no overlapping addresses and a word-order-sensitive codec — the map is internally coherent and wire-decodable. Does NOT prove byte-order or scaling match a real device: the emulator is seeded from the map's own types, so a uniformly wrong byte-order still round-trips. Only hardware-verified confirms byte-order/scale on the wire.

pointaddress (0-based)typescaleunit
Modbus TCP Register Layout Version4U161
Charging State5U161
Current L16U160.1A
Current L27U160.1A
Current L38U160.1A
Temperature (PCB)9I160.1°C
Voltage L1 - N10U161V
Voltage L2 - N11U161V
Voltage L3 - N12U161V
Extern Lock State13U161
Power14U161W
Energy since Power on15U32BE1VAh
Energy since Installation17U32BE1VAh
Energy during charge cycle19U32BE1VAh
Hardware configuration maximal current100U161A
Hardware configuration minimal current101U161A
Logistic String102U161
Logistic String103U161
Logistic String104U161
Logistic String105U161
Logistic String (end)133U161
Hardware Variant200U161
Application Software Revision203U161
WatchDog TimeOut257U160.001s
Remote Lock259U161
Maximal Current Command261U160.1A
FailSafe Current262U161A
Support Diagnostic Data (start)300U161
RFID Control Commands301U161
Charging Permission Command302U161
Support Diagnostic Data (end)318U161
Maximal Power Target Command500U161W
Phase Switch Control501U161
Charging Management Strategy502U161
Duration Time Phase Switch503U161s
Waiting Time Phase Switch504U161s
Disconnect Simulation Command505U161
Error Memory (end)819I161
Wallbox Serial Number (start)1000U161
Wallbox Serial Number (end)1017U161
Wallbox Item Number (start)1050U161
Wallbox Item Number (end)1067U161
Date of Production (start)1100U161
Date of Production (end)1117U161
Firmware Version (start)1250U161
Firmware Version (end)1290U161
Firmware Variant (start)1300U161
Firmware Variant (end)1340U161
RFID Card Counter2000U161
RFID UID Length2001U161
RFID UID Byte 0 and Byte 12002U161
RFID UID Byte 2 and Byte 32003U161
RFID UID Byte 4 and Byte 52004U161
RFID UID Byte 6 and Byte 72005U161
RFID UID Byte 8 up to Byte 92006U161
RFID UID Byte 10 and Byte 112007U161
RFID Card Serial Number Char 0 and Char 12008U161
RFID Card Serial Number Char 2 up to Char 32009U161
RFID Card Serial Number Char 4 up to Char 52010U161
RFID Card Serial Number Char 6 up to Char 72011U161
RFID Card Serial Number Char 8 up to Char 92012U161
RFID Card Serial Number Char 10 up to Char 112013U161
RFID Card Serial Number Char 12 up to Char 132014U161
RFID Card Serial Number Char 14 up to Char 152015U161
RFID Card Serial Number Char 16 up to Char 172016U161
RFID Card Serial Number Char 18 and Char 192017U161
RFID Security Type2018U161
Charging Permission2019U161
Wallbox Ready for Charging2020U161
RFID Status Information2100U161
Int. MID available3000U161
Int. MID Current L13001U160.1A
Int. MID Current L23002U160.1A
Int. MID Current L33003U160.1A
Int. MID Voltage L1 - N3004U161V
Int. MID Voltage L2 - N3005U161V
Int. MID Voltage L3 - N3006U161V
Int. MID Power Forward3007U161W
Int. MID Energy Forward since Installation3008U32BE1Wh
Int. MID Power Reverse3010U161W
Int. MID Energy Reverse since Installation3011U32BE1Wh
Int. MID Serial Number (start)3100U161
Int. MID Serial Number (end)3150U161
Int. MID Vendor Name (start)3151U161
Int. MID Vendor Name (end)3201U161
Int. MID Product Name (start)3202U161
Int. MID Product Name (end)3252U161
Int. MID Software Version (start)3253U161
Int. MID Software Version (end)3273U161
Int. MID Hardware Version (start)3274U161
Int. MID Hardware Version (end)3294U161
Internal HCB Current L13500U160.1A
Internal HCB Current L23501U160.1A
Internal HCB Current L33502U160.1A
Internal HCB Voltage L1 - N3503U161V
Internal HCB Voltage L2 - N3504U161V
Internal HCB Voltage L3 - N3505U161V
Internal HCB Power3506U161W
Internal HCB Energy since Power on3507U32BE1Wh
Internal HCB Energy since Installation3509U32BE1Wh
Ext. Current L14000U160.1A
Ext. Current L24001U160.1A
Ext. Current L34002U160.1A
Ext. Voltage L1 - N4003U161V
Ext. Voltage L2 - N4004U161V
Ext. Voltage L3 - N4005U161V
Ext. Power Meter: Power Forward4006U161W
Ext. Power Meter: Energy Forward since Installation4007U32BE1Wh
Ext. Power Meter: Power Reverse4009U161W
Ext. Power Meter: Energy Reverse since Installation4010U32BE1Wh
Ext. MID Serial Number (start)4100U161
Ext. MID Serial Number (end)4150U161
Ext. MID Vendor Name (start)4151U161
Ext. MID Vendor Name (end)4201U161
Ext. MID Product Name (start)4202U161
Ext. MID Product Name (end)4252U161
Ext. MID Software Version (start)4253U161
Ext. MID Software Version (end)4273U161
Ext. MID Hardware Version (start)4274U161
Ext. MID Hardware Version (end)4294U161
Maximal Power Set5000U161W
Phase Switch State5001U161
Status Charging Management Strategy5002U161
Status Disconnecting Simulation5003U161

link settings as documented (unverified): TCP; FC 03,04,06; The TCP port 502 is used for Modbus TCP communication. Only one connection can be established on this port at a time.

⚠ Please do not use registers that are not described in this document or are not intended for use by the user. — Starkest reads only; we never write a control register.

bench facts as documented (unverified)
serial register1000
firmware register1250
doc revision20240130
firmware applicabilityVersion 1.0.8 – Version 2.0.2
field reports — community-sourced, unverified (checked 2026-06-11)
  • confirmed: Modbus TCP framing on port 502 with single-connection limit — confirmed by Amperfied Wallbox Connect Series Modbus TCP Register Layout documentation [2.1.2]
  • confirmed: Function codes 3, 4, and 6 support — confirmed by Amperfied Wallbox Connect Series Modbus TCP Register Layout documentation
  • confirmed: Identification registers (Serial Number at 1000, Firmware Version at 1250) — confirmed by Amperfied Wallbox Connect Series Modbus TCP Register Layout documentation
  • confirmed: Register map layout (e.g., charging_state @ 5, current_l1 @ 6, watchdog_timeout @ 257, remote_lock @ 259, maximal_current_command @ 261) — confirmed by Amperfied Wallbox Connect Series Modbus TCP Register Layout documentation and Loxone Library integration

The trust ladder

Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.

Device not here? Upload its manual and get a checked map back. It's free.

Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.

Building on a lot of devices? License the library — machine-readable maps, the firmware matrix, and API access.