Crowcon Gasmaster III gas panel

Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.

structure-verified

Decode path is structurally sound (addresses, widths, finite values). Does NOT prove word order or scaling.

pointaddress (0-based)typescaleunit
Instrument identification1U161
Manufacturer2U161
Software version3U161
Instrument serial number4U161
System Name5U161
Modbus Address50U161
Modbus Stop bit Config51U161
Next Service Due52I32BE1s
Language53U161
System Type54U161
Menu Display Contrast55U161
Channel Display Contrast56U161
Common Relay Low Type57U161
Common Relay Low Energisation58U161
Common Relay High Type59U161
Common Relay High Energisation60U161
Common Relay Fault Type61U161
Common Relay Fault Energisation62U161
Sounder AV Drive type63U161
Beacon AV Drive type64U161
Supervisor Password65U161
System Clock Adjustment66I32BE1
Mains Fail Config67U161
Pellistor Saver Threshold68F32BE1%LEL
Ch1.Location100U161
Ch1.GasName101U161
Ch1.Type102U161
Ch1.Range103F32BE1
Ch1.Units104U161
Ch1.Alarm Low Level105F32BE1
Ch1.Alarm Low Hysteresis106F32BE1
Ch1.Alarm Low Sense107U161
Ch1.Relay Low Type108U161
Ch1.Relay Low Energisation109U161
Ch1.Alarm High Level110F32BE1
Ch1.Alarm High Sense111U161
Ch1.Relay High Type112U161
Ch1.Relay High Energisation113U161
Ch1.Interpret Low114U161
Ch1.Apply ZFS115U161
Ch1.Fire Reset Time116U161s
Ch1.Stabilisation Time117U161s
Ch1.Alarm 1 Silent118U161
Ch1.Input zero119F32BE1
Ch1.Input scale120F32BE1
Ch1.Output zero121F32BE1
Ch1.Output scale122F32BE1
Ch1.Input Scale Limit123F32BE1
Ch2.Location200U161
Ch2.GasName201U161
Ch2.Type202U161
Ch2.Range203F32BE1
Ch2.Units204U161
Ch2.Alarm Low Level205F32BE1
Ch2.Alarm Low Hysteresis206F32BE1
Ch2.Alarm Low Sense207U161
Ch2.Relay Low Type208U161
Ch2.Relay Low Energisation209U161
Ch2.Alarm High Level210F32BE1
Ch2.Alarm High Sense211U161
Ch2.Relay High Type212U161
Ch2.Relay High Energisation213U161
Ch2.Interpret Low214U161
Ch2.Apply ZFS215U161
Ch2.Fire Reset Time216U161s
Ch2.Stabilisation Time217U161s
Ch2.Alarm 1 Silent218U161
Ch2.Input zero219F32BE1
Ch2.Input scale220F32BE1
Ch2.Output zero221F32BE1
Ch2.Output scale222F32BE1
Ch2.Input Scale Limit223F32BE1
Ch3.Location300U161
Ch3.GasName301U161
Ch3.Type302U161
Ch3.Range303F32BE1
Ch3.Units304U161
Ch3.Alarm Low Level305F32BE1
Ch3.Alarm Low Hysteresis306F32BE1
Ch3.Alarm Low Sense307U161
Ch3.Relay Low Type308U161
Ch3.Relay Low Energisation309U161
Ch3.Alarm High Level310F32BE1
Ch3.Alarm High Sense311U161
Ch3.Relay High Type312U161
Ch3.Relay High Energisation313U161
Ch3.Interpret Low314U161
Ch3.Apply ZFS315U161
Ch3.Fire Reset Time316U161s
Ch3.Stabilisation Time317U161s
Ch3.Alarm 1 Silent318U161
Ch3.Input zero319F32BE1
Ch3.Input scale320F32BE1
Ch3.Output zero321F32BE1
Ch3.Output scale322F32BE1
Ch3.Input Scale Limit323F32BE1
Ch4.Location400U161
Ch4.GasName401U161
Ch4.Type402U161
Ch4.Range403F32BE1
Ch4.Units404U161
Ch4.Alarm Low Level405F32BE1
Ch4.Alarm Low Hysteresis406F32BE1
Ch4.Alarm Low Sense407U161
Ch4.Relay Low Type408U161
Ch4.Relay Low Energisation409U161
Ch4.Alarm High Level410F32BE1
Ch4.Alarm High Sense411U161
Ch4.Relay High Type412U161
Ch4.Relay High Energisation413U161
Ch4.Interpret Low414U161
Ch4.Apply ZFS415U161
Ch4.Fire Reset Time416U161s
Ch4.Stabilisation Time417U161s
Ch4.Alarm 1 Silent418U161
Ch4.Input zero419F32BE1
Ch4.Input scale420F32BE1
Ch4.Output zero421F32BE1
Ch4.Output scale422F32BE1
Ch4.Input Scale Limit423F32BE1
Time500U32BE1s
Status501U161
System Fault 1502U32BE1
System Fault 2503U32BE1
System Warning 1504U32BE1
System Warning 2505U32BE1
Channel 1 Level506F32BE1
Channel 1 Status507U161
Channel 2 Level508F32BE1
Channel 2 Status509U161
Channel 3 Level510F32BE1
Channel 3 Status511U161
Channel 4 Level512F32BE1
Channel 4 Status513U161
Channel 1 Inhibit540U161
Channel 1 Action Zero541U161
Channel 1 Cal Level542F32BE1
Channel 1 Cal Action543U161
Channel 1 OP Cal Control544U161
Channel 1 OP Cal Level545F32BE1
Channel 1 Pellistor saver disabled546U161
Channel 2 Inhibit550U161
Channel 2 Action Zero551U161
Channel 2 Cal Level552F32BE1
Channel 2 Cal Action553U161
Channel 2 OP Cal Control554U161
Channel 2 OP Cal Level555F32BE1
Channel 2 Pellistor saver disabled556U161
Channel 3 Inhibit560U161
Channel 3 Action Zero561U161
Channel 3 Cal Level562F32BE1
Channel 3 Cal Action563U161
Channel 3 OP Cal Control564U161
Channel 3 OP Cal Level565F32BE1
Channel 3 Pellistor saver disabled566U161
Channel 4 Inhibit570U161
Channel 4 Action Zero571U161
Channel 4 Cal Level572F32BE1
Channel 4 Cal Action573U161
Channel 4 OP Cal Control574U161
Channel 4 OP Cal Level575F32BE1
Channel 4 Pellistor saver disabled576U161
Accept Reset600U161
NVM control601U161
Protection602U161
Power Up Test603U161
Relay Stimulation Sequence604U161
Relay Monitor605U161
Analogue Out1 Stimulation606U161
Analogue Out2 Stimulation607U161
Analogue Out3 Stimulation608U161
Analogue Out4 Stimulation609U161
DAC0 Output610U161
DAC1 Output611U161
Indicator Stimulation612U161
Chan LCD Test613U161
Chan LCD Seq614U161
Menu LCD Test615U161
Menu LCD Seq616U161
LCD Backlight617U161
MUX control – Ch1618U161
MUX control – Ch2619U161
MUX control – Ch3620U161
MUX control – Ch4621U161
Raw ADC – Ch1622U161
Raw ADC – Ch2623U161
Raw ADC – Ch3624U161
Raw ADC – Ch4625U161
Raw ADC – PSU626U161
Raw ADC – Vsys627U161
Raw ADC – P12V628U161
Raw ADC – Check Low629U161
Raw ADC – Check High630U161
Raw ADC – VLCD0631U161
Raw ADC – VLCD1632U161
Button633U161
Fire Reset634U161
Battery Switch635U161
Read control700U161
Service event time and date701U32BE1s
Event 1 time702U32BE1
Event 1 IDs703U161
Event 1 data word704U32BE1
Event 2 time705U32BE1
Event 2 IDs706U161
Event 2 data word707U32BE1
Event 3 time708U32BE1
Event 3 IDs709U161
Event 3 data word710U32BE1
Event 4 time711U32BE1
Event 4 IDs712U161
Event 4 data word713U32BE1
Event 5 time714U32BE1
Event 5 IDs715U161
Event 5 data word716U32BE1
Event 6 time717U32BE1
Event 6 IDs718U161
Event 6 data word719U32BE1
Event 7 time720U32BE1
Event 7 Ids721U161
Event 7 data word722U32BE1
Event 8 time723U32BE1
Event 8 Ids724U161
Event 8 data word725U32BE1
Event 9 time726U32BE1
Event 9 Ids727U161
Event 9 data word728U32BE1
Event 10 time729U32BE1
Event 10 Ids730U161
Event 10 data word731U32BE1
Text string ident800U161
Text string length (L)801U161
Primary language text802U161
Configurable language text803U161

link settings as documented (unverified): RTU; default 9600 8N1; unit ID 1; FC 03,16; A silent interval of 5.7mS is used to define the termination of a data packet. On receipt of a message requiring a response, the instrument will pause for a guaranteed period of at least 50mS before transmission will commence.

bench facts as documented (unverified)
inter-frame delay5 ms
broadcastsupported
protocol notesOn receipt of a message requiring a response, the instrument will pause for a guaranteed period of at least 50mS before transmission will commence.
model register1
serial register4
firmware register3
identification notesManufacturer is at address 2.
FC 43 device IDnot supported
doc revisionFGM3-002 Issue 2 January 2015
field reports — community-sourced, unverified (checked 2026-06-11)
  • confirmed: Document revision FGM3-002 Issue 2 January 2015 — confirmed by Crowcon Gasmaster Modbus Instructions document [1.1.1]
  • confirmed: Baud rate 9600, RTU framing, and 1 stop bit (configurable) — confirmed by Crowcon Gasmaster Modbus Instructions Section 2.1
  • confirmed: Silent interval of 5.7mS and response pause of at least 50mS — confirmed by Crowcon Gasmaster Modbus Instructions Section 2.2
  • confirmed: Instrument identification registers (Model @ 1, Manufacturer @ 2, Software version @ 3, Serial @ 4) — confirmed by Crowcon Gasmaster Modbus Instructions Section 3.1
  • confirmed: Runtime registers (Time @ 500, Status @ 501, System Fault 1 @ 502, System Fault 2 @ 503) — confirmed by Crowcon Gasmaster Modbus Instructions Section 3.4
  • confirmed: Raw ADC registers (Raw ADC Ch1 @ 622 through Raw ADC VLCD1 @ 632) — confirmed by Crowcon Gasmaster Modbus Instructions Section 3.4

The trust ladder

Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.