Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.
Round-trips through a real Modbus stack with no overlapping addresses and a word-order-sensitive codec — the map is internally coherent and wire-decodable. Does NOT prove byte-order or scaling match a real device: the emulator is seeded from the map's own types, so a uniformly wrong byte-order still round-trips. Only hardware-verified confirms byte-order/scale on the wire.
| point | address (0-based) | type | scale | unit |
|---|---|---|---|---|
| eScale | 512 | U32BE | 1 | |
| kWh | 514 | U32BE | 1 | kWh |
| kVAh | 516 | U32BE | 1 | kVAh |
| kvarh Inductive | 518 | U32BE | 1 | kvarh |
| kvarh Capacitive | 520 | U32BE | 1 | kvarh |
| Import kvarh | 522 | U32BE | 1 | kvarh |
| Export kWh | 524 | U32BE | 1 | kWh |
| Export kvarh | 526 | U32BE | 1 | kvarh |
| Hours Run | 528 | U32BE | 1 | hours |
| System kW | 2816 | I16 | 1 | |
| System kVA | 2817 | I16 | 1 | |
| System kvar | 2818 | I16 | 1 | |
| System PF | 2819 | I16 | 0.001 | |
| Frequency | 2820 | I16 | 0.1 | |
| Phase 1 Volts | 2821 | I16 | 1 | |
| Phase 1 Amps | 2822 | I16 | 1 | |
| Phase 1 kW | 2823 | I16 | 1 | |
| Phase 2 Volts | 2824 | I16 | 1 | |
| Phase 2 Amps | 2825 | I16 | 1 | |
| Phase 2 kW | 2826 | I16 | 1 | |
| Phase 3 Volts | 2827 | I16 | 1 | |
| Phase 3 Amps | 2828 | I16 | 1 | |
| Phase 3 kW | 2829 | I16 | 1 | |
| Phase 1 PF | 2830 | I16 | 0.001 | |
| Phase 2 PF | 2831 | I16 | 0.001 | |
| Phase 3 PF | 2832 | I16 | 0.001 | |
| Ph1-Ph2 Volts | 2833 | I16 | 1 | |
| Ph2-Ph3 Volts | 2834 | I16 | 1 | |
| Ph3-Ph1 Volts | 2835 | I16 | 1 | |
| Neutral Current | 2836 | I16 | 1 | |
| Amps Scale Ki | 2837 | I16 | 1 | |
| Phase Volts Scale Kvp | 2838 | I16 | 1 | |
| Line Volts Scale Kvl | 2839 | I16 | 1 | |
| Power Scale Kp | 2840 | I16 | 1 | |
| Phase 1 kVA | 3072 | I16 | 1 | |
| Phase 2 kVA | 3073 | I16 | 1 | |
| Phase 3 kVA | 3074 | I16 | 1 | |
| Phase 1 kvar | 3075 | I16 | 1 | |
| Phase 2 kvar | 3076 | I16 | 1 | |
| Phase 3 kvar | 3077 | I16 | 1 | |
| Peak Hold Ph1 Amps | 3328 | I16 | 1 | |
| Peak Hold Ph2 Amps | 3329 | I16 | 1 | |
| Peak Hold Ph3 Amps | 3330 | I16 | 1 | |
| Peak Hold Ph1 Volts | 3331 | I16 | 1 | |
| Peak Hold Ph2 Volts | 3332 | I16 | 1 | |
| Peak Hold Ph3 Volts | 3333 | I16 | 1 | |
| Peak Hold kW Demand | 3334 | U16 | 1 | |
| KW Demand Period | 3335 | U16 | 1 | Minutes |
| KW Demand | 3336 | U16 | 1 | |
| KVA Demand | 3337 | U16 | 1 | |
| Peak Hold kVA Demand | 3338 | U16 | 1 | |
| Kvar Demand | 3339 | U16 | 1 | |
| Peak Hold kvar Demand | 3340 | U16 | 1 | |
| CT Primary | 3584 | U16 | 1 | Amps |
| Nominal Volts | 3585 | U16 | 1 | Volts |
| Pulse 1 Rate | 3586 | U16 | 1 | Counts/Pulse |
| Pulse 2 Rate | 3587 | U16 | 1 | Counts/Pulse |
| Baud | 3588 | U16 | 1 | |
| Modbus ID | 3589 | U16 | 1 | |
| Meter Model | 3590 | U16 | 1 | |
| Meter Type | 3591 | U16 | 1 | |
| Firmware Version | 3592 | U16 | 1 | |
| Current Demand Period | 3593 | U16 | 1 | |
| Pulse ON Time | 3594 | U16 | 1 | |
| Security Code | 3595 | U16 | 1 | |
| Hours Run Limit | 3596 | U16 | 1 | |
| PT Scaling Factor | 3597 | U16 | 1 | |
| Peak Ph1 Amps Demand | 3840 | U16 | 1 | |
| Peak Ph2 Amps Demand | 3841 | U16 | 1 | |
| Peak Ph3 Amps Demand | 3842 | U16 | 1 | |
| Peak Ph1 Volts Demand | 3843 | U16 | 1 | |
| Peak Ph2 Volts Demand | 3844 | U16 | 1 | |
| Peak Ph3 Volts Demand | 3845 | U16 | 1 | |
| Ph1 Amps Demand | 4096 | U16 | 1 | |
| Ph2 Amps Demand | 4097 | U16 | 1 | |
| Ph3 Amps Demand | 4098 | U16 | 1 | |
| Ph1 Volts Demand | 4099 | U16 | 1 | |
| Ph2 Volts Demand | 4100 | U16 | 1 | |
| Ph3 Volts Demand | 4101 | U16 | 1 | |
| V1 % THD | 4352 | U16 | 0.1 | % |
| V2 % THD | 4353 | U16 | 0.1 | % |
| V3 % THD | 4354 | U16 | 0.1 | % |
| I1 % THD | 4355 | U16 | 0.1 | % |
| I2 % THD | 4356 | U16 | 0.1 | % |
| I3 % THD | 4357 | U16 | 0.1 | % |
| kW Demand | 4608 | I16 | 1 | |
| kVA Demand | 4609 | I16 | 1 | |
| Kvar Demand | 4610 | I16 | 1 | |
| Peak Hold kW Demand | 4611 | I16 | 1 | |
| Peak Hold kVA Demand | 4612 | I16 | 1 | |
| Peak Hold kvar Demand | 4613 | I16 | 1 | |
| KWh High Word | 7680 | U16 | 1 | |
| KWh Low Word | 7681 | U16 | 1 | |
| KVAh High Word | 7682 | U16 | 1 | |
| KVAh Low Word | 7683 | U16 | 1 | |
| Kvarh High Word | 7684 | U16 | 1 | |
| Kvarh Low Word | 7685 | U16 | 1 | |
| Export kWh High Word | 7686 | U16 | 1 | |
| Export kWh Low Word | 7687 | U16 | 1 | |
| Phase 1 Amps | 7688 | I16 | 1 | |
| Phase 2 Amps | 7689 | I16 | 1 | |
| Phase 3 Amps | 7690 | I16 | 1 | |
| Phase 1 Volts | 7691 | I16 | 1 | |
| Phase 2 Volts | 7692 | I16 | 1 | |
| Phase 3 Volts | 7693 | I16 | 1 | |
| Ph1-Ph2 Volts | 7694 | I16 | 1 | |
| Ph2-Ph3 Volts | 7695 | I16 | 1 | |
| Ph3-Ph1 Volts | 7696 | I16 | 1 | |
| Frequency | 7697 | I16 | 0.1 | |
| Phase 1 PF | 7698 | I16 | 0.001 | |
| Phase 2 PF | 7699 | I16 | 0.001 | |
| Phase 3 PF | 7700 | I16 | 0.001 | |
| System PF | 7701 | I16 | 0.001 | |
| Phase 1 kW | 7702 | I16 | 1 | |
| Phase 2 kW | 7703 | I16 | 1 | |
| Phase 3 kW | 7704 | I16 | 1 | |
| System kW | 7705 | I16 | 1 | |
| Phase 1 kVA | 7706 | I16 | 1 | |
| Phase 2 kVA | 7707 | I16 | 1 | |
| Phase 3 kVA | 7708 | I16 | 1 | |
| System kVA | 7709 | I16 | 1 | |
| Phase 1 kvar | 7710 | I16 | 1 | |
| Phase 2 kvar | 7711 | I16 | 1 | |
| Phase 3 kvar | 7712 | I16 | 1 | |
| System kvar | 7713 | I16 | 1 | |
| Ph1 Amps Demand | 7714 | U16 | 1 | |
| Ph2 Amps Demand | 7715 | U16 | 1 | |
| Ph3 Amps Demand | 7716 | U16 | 1 | |
| Ph1 Volts Demand | 7717 | U16 | 1 | |
| Ph2 Volts Demand | 7718 | U16 | 1 | |
| Ph3 Volts Demand | 7719 | U16 | 1 | |
| Peak Ph1 Amps | 7720 | I16 | 1 | |
| Peak Ph2 Amps | 7721 | I16 | 1 | |
| Peak Ph3 Amps | 7722 | I16 | 1 | |
| Peak Ph1 Volts | 7723 | I16 | 1 | |
| Peak Ph2 Volts | 7724 | I16 | 1 | |
| Peak Ph3 Volts | 7725 | I16 | 1 | |
| kW Demand | 7726 | I16 | 1 | |
| kVA Demand | 7727 | I16 | 1 | |
| kvar Demand | 7728 | I16 | 1 | |
| Peak Hold kW Demand | 7729 | I16 | 1 | |
| Peak Hold kVA Demand | 7730 | I16 | 1 | |
| Peak Hold kvar Demand | 7731 | I16 | 1 | |
| Neutral Current | 7732 | I16 | 1 | |
| Amps Scale Ki | 7733 | I16 | 1 | |
| Phase Volts Scale Kvp | 7734 | I16 | 1 | |
| Line Volts Scale Kvl | 7735 | I16 | 1 | |
| Power Scale Kp | 7736 | I16 | 1 | |
| Energy Scale Ke | 7737 | I16 | 1 | |
| V1: 2nd Harmonic | 7936 | U16 | 0.1 | % |
| V1: 3rd Harmonic | 7937 | U16 | 0.1 | % |
| V1: 4th Harmonic | 7938 | U16 | 0.1 | % |
| V1: 5th Harmonic | 7939 | U16 | 0.1 | % |
| V1: 6th Harmonic | 7940 | U16 | 0.1 | % |
| V1: 7th Harmonic | 7941 | U16 | 0.1 | % |
| V1: 8th Harmonic | 7942 | U16 | 0.1 | % |
| V1: 9th Harmonic | 7943 | U16 | 0.1 | % |
| V1: 10th Harmonic | 7944 | U16 | 0.1 | % |
| V1: 11th Harmonic | 7945 | U16 | 0.1 | % |
| V1: 12th Harmonic | 7946 | U16 | 0.1 | % |
| V1: 13th Harmonic | 7947 | U16 | 0.1 | % |
| V1: 14th Harmonic | 7948 | U16 | 0.1 | % |
| V1: 15th Harmonic | 7949 | U16 | 0.1 | % |
| V2: 2nd Harmonic | 8192 | U16 | 0.1 | % |
| V2: 3rd Harmonic | 8193 | U16 | 0.1 | % |
| V2: 4th Harmonic | 8194 | U16 | 0.1 | % |
| V2: 5th Harmonic | 8195 | U16 | 0.1 | % |
| V2: 6th Harmonic | 8196 | U16 | 0.1 | % |
| V2: 7th Harmonic | 8197 | U16 | 0.1 | % |
| V2: 8th Harmonic | 8198 | U16 | 0.1 | % |
| V2: 9th Harmonic | 8199 | U16 | 0.1 | % |
| V2: 10th Harmonic | 8200 | U16 | 0.1 | % |
| V2: 11th Harmonic | 8201 | U16 | 0.1 | % |
| V2: 12th Harmonic | 8202 | U16 | 0.1 | % |
| V2: 13th Harmonic | 8203 | U16 | 0.1 | % |
| V2: 14th Harmonic | 8204 | U16 | 0.1 | % |
| V2: 15th Harmonic | 8205 | U16 | 0.1 | % |
| V3: 2nd Harmonic | 8448 | U16 | 0.1 | % |
| V3: 3rd Harmonic | 8449 | U16 | 0.1 | % |
| V3: 4th Harmonic | 8450 | U16 | 0.1 | % |
| V3: 5th Harmonic | 8451 | U16 | 0.1 | % |
| V3: 6th Harmonic | 8452 | U16 | 0.1 | % |
| V3: 7th Harmonic | 8453 | U16 | 0.1 | % |
| V3: 8th Harmonic | 8454 | U16 | 0.1 | % |
| V3: 9th Harmonic | 8455 | U16 | 0.1 | % |
| V3 10th Harmonic | 8456 | U16 | 0.1 | % |
| V3: 11th Harmonic | 8457 | U16 | 0.1 | % |
| V3: 12th Harmonic | 8458 | U16 | 0.1 | % |
| V3: 13th Harmonic | 8459 | U16 | 0.1 | % |
| V3: 14th Harmonic | 8460 | U16 | 0.1 | % |
| V3: 15th Harmonic | 8461 | U16 | 0.1 | % |
| I1: 2nd Harmonic | 8704 | U16 | 0.1 | % |
| I1: 3rd Harmonic | 8705 | U16 | 0.1 | % |
| I1: 4th Harmonic | 8706 | U16 | 0.1 | % |
| I1: 5th Harmonic | 8707 | U16 | 0.1 | % |
| I1: 6th Harmonic | 8708 | U16 | 0.1 | % |
| I1: 7th Harmonic | 8709 | U16 | 0.1 | % |
| I1: 8th Harmonic | 8710 | U16 | 0.1 | % |
| I1: 9th Harmonic | 8711 | U16 | 0.1 | % |
| I1: 10th Harmonic | 8712 | U16 | 0.1 | % |
| I1: 11th Harmonic | 8713 | U16 | 0.1 | % |
| I1: 12th Harmonic | 8714 | U16 | 0.1 | % |
| I1: 13th Harmonic | 8715 | U16 | 0.1 | % |
| I1: 14th Harmonic | 8716 | U16 | 0.1 | % |
| I1: 15th Harmonic | 8717 | U16 | 0.1 | % |
| I2: 2nd Harmonic | 8960 | U16 | 0.1 | % |
| I2: 3rd Harmonic | 8961 | U16 | 0.1 | % |
| I2: 4th Harmonic | 8962 | U16 | 0.1 | % |
| I2: 5th Harmonic | 8963 | U16 | 0.1 | % |
| I2: 6th Harmonic | 8964 | U16 | 0.1 | % |
| I2: 7th Harmonic | 8965 | U16 | 0.1 | % |
| I2: 8th Harmonic | 8966 | U16 | 0.1 | % |
| I2: 9th Harmonic | 8967 | U16 | 0.1 | % |
| I2: 10th Harmonic | 8968 | U16 | 0.1 | % |
| I2: 11th Harmonic | 8969 | U16 | 0.1 | % |
| I2: 12th Harmonic | 8970 | U16 | 0.1 | % |
| I2: 13th Harmonic | 8971 | U16 | 0.1 | % |
| I2: 14th Harmonic | 8972 | U16 | 0.1 | % |
| I2: 15th Harmonic | 8973 | U16 | 0.1 | % |
| I3: 2nd Harmonic | 9216 | U16 | 0.1 | % |
| I3: 3rd Harmonic | 9217 | U16 | 0.1 | % |
| I3: 4th Harmonic | 9218 | U16 | 0.1 | % |
| I3: 5th Harmonic | 9219 | U16 | 0.1 | % |
| I3: 6th Harmonic | 9220 | U16 | 0.1 | % |
| I3: 7th Harmonic | 9221 | U16 | 0.1 | % |
| I3: 8th Harmonic | 9222 | U16 | 0.1 | % |
| I3: 9th Harmonic | 9223 | U16 | 0.1 | % |
| I3: 10th Harmonic | 9224 | U16 | 0.1 | % |
| I3: 11th Harmonic | 9225 | U16 | 0.1 | % |
| I3: 12th Harmonic | 9226 | U16 | 0.1 | % |
| I3: 13th Harmonic | 9227 | U16 | 0.1 | % |
| I3: 14th Harmonic | 9228 | U16 | 0.1 | % |
| I3: 15th Harmonic | 9229 | U16 | 0.1 | % |
| Custom Address 0 | 19200 | U16 | 1 | |
| Custom Address 1 | 19201 | U16 | 1 | |
| Custom Address 2 | 19202 | U16 | 1 | |
| Custom Address 3 | 19203 | U16 | 1 | |
| Custom Address 4 | 19204 | U16 | 1 | |
| Custom Address 5 | 19205 | U16 | 1 | |
| Custom Address 6 | 19206 | U16 | 1 | |
| Custom Address 7 | 19207 | U16 | 1 | |
| Custom Address 8 | 19208 | U16 | 1 | |
| Custom Address 9 | 19209 | U16 | 1 | |
| Custom Address 10 | 19210 | U16 | 1 | |
| Custom Address 11 | 19211 | U16 | 1 | |
| Custom Address 12 | 19212 | U16 | 1 | |
| Custom Address 13 | 19213 | U16 | 1 | |
| Custom Address 14 | 19214 | U16 | 1 | |
| Custom Address 15 | 19215 | U16 | 1 | |
| Custom Address 16 | 19216 | U16 | 1 | |
| Custom Address 17 | 19217 | U16 | 1 | |
| Custom Address 18 | 19218 | U16 | 1 | |
| Custom Address 19 | 19219 | U16 | 1 | |
| Custom Address 20 | 19220 | U16 | 1 | |
| Custom Address 21 | 19221 | U16 | 1 | |
| Custom Address 22 | 19222 | U16 | 1 | |
| Custom Address 23 | 19223 | U16 | 1 | |
| Custom Address 24 | 19224 | U16 | 1 | |
| Custom Address 25 | 19225 | U16 | 1 | |
| Custom Address 26 | 19226 | U16 | 1 | |
| Custom Address 27 | 19227 | U16 | 1 | |
| Custom Address 28 | 19228 | U16 | 1 | |
| Custom Address 29 | 19229 | U16 | 1 | |
| Custom Address 30 | 19230 | U16 | 1 | |
| Custom Address 31 | 19231 | U16 | 1 |
⚠ The Cube400 is intended for connection to dangerous voltages giving a risk of electric shock. Refer to the safety/installation instructions in the Cube400 Installation Guide before connecting the communications. — Starkest reads only; we never write a control register.
| terminals | Rising clamp, max wire 4mm2 |
| termination | Two 120 Ohm resistors recommended |
| isolation | 3.5kV (1 minute) RS485 Port from all other circuit |
| shield/ground | Shield should be connected to ground at the host (PC) only. The cable shield should not be used as the 0V connection. |
| wiring notes | 3-Pairs of terminals, internally shorted, are provided for convenience. |
| max registers/read | 20 |
| response timeout | 250 ms |
| inter-frame delay | 5 ms |
| broadcast | supported |
| protocol notes | Exception codes 1 and 2 are supported. |
| model register | 3590 |
| firmware register | 3592 |
| identification notes | Meter Type is at register 3591. |
| power | Internally supplied from Cube400 Auxiliary. Requires additional 1W max |
| doc revision | Revision 5, July 2016 |
Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.
Device not here? Upload its manual and get a checked map back. It's free.
Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.