device library

phoenix-contact-ev-charge-control-em-cp-pp-eth

Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.

structure-verified

Decode path is structurally sound (addresses, widths, finite values). Does NOT prove word order or scaling.

pointaddress (0-based)typescaleunit
EV status100U161
Proximity charging current101U161A
Charging time102U32BE1s
DIP switch configuration104U161
Firmware version105U32BE1
Error codes107U161
Display meter voltage V1108U32BE1
Display meter voltage V2110U32BE1
Display meter voltage V3112U32BE1
Display meter current I1114U32BE1
Display meter current I2116U32BE1
Display meter current I3118U32BE1
Display meter real power120U32BE1
Display meter reactive power122U32BE1
Display meter apparent power124U32BE1
Display meter power factor126U32BE1
Display meter energy128U32BE1
Display meter maximum power130U32BE1
Energy of current charging process132U32BE1
Display meter mains frequency134U32BE1
Display meter maximum current I1136U32BE1
Display meter maximum current I2138U32BE1
Display meter maximum current I3140U32BE1
Status of overcurrent shutdown142U161
Digital input EN (Enable)200U161
Digital input XR (External Release)201U161
Digital input LD (Lock Detection)202U161
Digital input ML (Manual Lock)203U161
Digital output CR (Charger Ready)204U161
Digital output LR (Locking Request)205U161
Digital output VR (Vehicle Ready)206U161
Digital output ER (Error)207U161
Set charging current (PWM signal)300U161A
MAC address301U161
Serial number304U161
Device name310U161
IP address315U161
Subnet mask319U161
Gateway323U161
Definition of output CR327U161
Definition of output LR328U161
Definition of output VR329U161
Definition of output ER330U161
Voltage V1331U161
Voltage V2332U161
Voltage V3333U161
Current I1334U161
Current I2335U161
Current I3336U161
Real power337U161
Reactive power338U161
Apparent power339U161
Power factor340U161
Energy meter total341U161
Maximum power (current charging process)342U161
Energy meter can be reset343U161
Mains frequency344U161
Maximum current I1345U161
Maximum current I2346U161
Maximum current I3347U161
Reset register 1348U161
Reset value 1349U161
Reset register 2350U161
Reset value 2351U161
Voltage V1352F32BE1
Voltage V2354F32BE1
Voltage V3356F32BE1
Current I1358F32BE1
Current I2360F32BE1
Current I3362F32BE1
Real power364F32BE1
Reactive power366F32BE1
Apparent power368F32BE1
Power factor370F32BE1
Energy meter total372F32BE1
Maximum power (current charging process)374F32BE1
Energy meter can be reset376F32BE1
Mains frequency378F32BE1
Maximum current I1380F32BE1
Maximum current I2382F32BE1
Maximum current I3384F32BE1
Baud rate for communication to energy meter386U32BE1
Modbus address of energy meter388U161
Polling cycle of energy meter389U161ms
Activation of the charging contactor390U161
Name of energy meter391U161
Enable charging process400U161
Request digital communication401U161
Charging station available402U161
Manual locking403U161
Switch DHCP on/off404U161
Output 1405U161
Output 2406U161
Output 3407U161
Output 4408U161
Activate overcurrent shutdown409U161
Byte sequence410U161
"Voltage in status A/B detected" function activated411U161
"Status D, reject vehicle" function activated412U161
Reset charging controller413U161
Voltage in status A/B detected414U161
Status D, vehicle rejected415U161
Configuration of input ML416U161
Voltage V1500U161
Voltage V2501U161
Voltage V3502U161
Current I1503U161
Current I2504U161
Current I3505U161
Real power506U161
Reactive power507U161
Apparent power508U161
Power factor509U161
Energy meter total510U161
Maximum power (current charging process)511U161
Energy meter can be reset512U161
Mains frequency513U161
Maximum current I1514U161
Maximum current I2515U161
Maximum current I3516U161
Reset 1517U161
Reset 2518U161
Delay before contactor monitoring after ending the charging process519U161ms

The trust ladder

Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.

Device not here? Upload its manual and get a checked map back. It's free.

Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.

Building on a lot of devices? License the library — machine-readable maps, the firmware matrix, and API access.