pointaddress (0-based)typescaleunit
Protocol No.4949U32BE1
Protocol ver.4951U32BE1
LCD Software Version4953U161
DSP software version4968U161
SN (Serial Number)4989U161
Device type code4999U161
Nominal output power5000U160.1kW
Output type5001U161
Daily power yields5002U160.1kWh
Total power yields5003U32BE1kWh
System clock Second5004U161
Total running time5005U32BE1h
Active Power control5006U161
Internal temperature5007I160.1DegC
Total Apparent Power5008U32BE1VA
DC Voltage15010U160.1V
DC current15011U160.1A
Total DC power5016U32BE1W
A-B line voltage Or Phase A voltage5018U160.1V
B-C Line Voltage Or Phase B Voltage5019U160.1V
C-A Line Voltage Or Phase C Voltage5020U160.1V
Phase A current5021U160.1A
Phase B current5022U160.1A
Phase C current5023U160.1A
Total active power5030U32BE1W
Reactive power5032I32BE1var
Reserved5033U161
Power factor5034I160.001
Grid frequency5035U160.1Hz
Reactive power percentage setting5036I160.1%
Inverter operating state5037U161
Fault/Alarm time: Year5038U161
Fault/Alarm time: Month5039U161
Fault/Alarm time: Day5040U161
Fault/Alarm time: Hour5041U161hrs
Fault/Alarm time: Minute5042U161min
Fault/Alarm time: Second5043U161sec
Fault/Alarm code 15044U161
Normal Reactive Output Power5048U160.1kvar
Lower Power5050U160.1
Upper Power5051U160.1
Upper limit-PF(Cap)5052U160.001
Lower limit-PF_Ind5053U160.001
Reserved5054U161
Impedance to the ground in parallel connection5070U161kOhm
Device Work state5080U32BE1
Upper U Limit5081U160.1
U1 Limit5082U160.1
U2 Limit5083U160.1
Hysteresis5084U160.1
Lower Q/Sn5085U160.1
Upper Q/Sn5086U160.1
Reserved5087U161
Daily running time5112U161min
Present country5113U161
Monthly power yields5127U32BE0.1kWh
Negative voltage to the ground5145I160.1V
Bus voltage5146U160.1V
Grid frequency5147U160.01Hz
Fan Status5151U161
C_SunSpec_ID40000U32BE1
C_SunSpec_DID40002U161
C_SunSpec_Length40003U161
C_Manufacturer40004U161
C_Model40020U161
C_Options40036U161
C_Version40044U161
C_SerialNumber40052U161
C_DeviceAddress40068U161
C_SunSpec_DID40070U161
C_SunSpec_Length40071U161
I_AC_Current40072U160.1A
I_AC_CurrentA40073U160.1A
I_AC_CurrentB40074U160.1A
I_AC_CurrentC40075U160.1A
I_AC_Current_SF40076I161
I_AC_VoltageAB40077U160.1V
I_AC_VoltageBC40078U160.1V
I_AC_VoltageCA40079U160.1V
I_AC_VoltageAN40080U161
I_AC_VoltageBN40081U161
I_AC_VoltageCN40082U161
I_AC_Voltage_SF40083I161
I_AC_Power40084I161
I_AC_Power_SF40085I161
I_AC_Frequency40086U161
I_AC_Frequency_SF40087I160.01Hz
I_AC_VA40088I161
I_AC_VA_SF40089I161
I_AC_VAR40090I161
I_AC_VAR_SF40091I161
I_AC_PF40092I161
I_AC_PF_SF40093I161
I_AC_Energy_WH40094U32BE1
I_AC_Energy_WH_SF40096I161
I_DC_Current40097U161A
I_DC_Current_SF40098I161
I_DC_Voltage40099U161A
I_DC_Voltage_SF40100I161
I_DC_Power40101I161
I_DC_Power_SF40102I161
I_Temp_Cab40103I161
I_Temp_Other40106I161
I_Temp_SF40107I161
I_Status40108U161
I_Status_Vendor40109U161
I_Event_140110U32BE1

The trust ladder

Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.

Device not here? Upload its manual and get a checked map back. It's free.

Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.

Building on a lot of devices? License the library — machine-readable maps, the firmware matrix, and API access.