Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.
Round-trips through a real Modbus stack with no overlapping addresses and a word-order-sensitive codec — the map is internally coherent and wire-decodable. Does NOT prove byte-order or scaling match a real device: the emulator is seeded from the map's own types, so a uniformly wrong byte-order still round-trips. Only hardware-verified confirms byte-order/scale on the wire.
| point | address (0-based) | type | scale | unit |
|---|---|---|---|---|
| modbus_address | 40 | U16 | 1 | |
| device_number | 41 | U16 | 1 | |
| system_instance | 42 | U16 | 1 | |
| configuration_status | 53 | U16 | 1 | |
| configuration_refresh_counter | 54 | U32BE | 1 | |
| device_state | 64 | U16 | 1 | |
| device_present | 65 | U16 | 1 | |
| inverter_enabled | 66 | U16 | 1 | |
| charger_enabled | 67 | U16 | 1 | |
| active_faults_flag | 68 | U16 | 1 | |
| active_warnings_flag | 69 | U16 | 1 | |
| charge_mode_status | 70 | U16 | 1 | |
| fault_bitmap_0 | 71 | U16 | 1 | |
| fault_bitmap_1 | 72 | U16 | 1 | |
| fault_bitmap_2 | 73 | U16 | 1 | |
| warning_bitmap_0 | 74 | U16 | 1 | |
| inverter_status | 75 | U16 | 1 | |
| configuration_errors | 76 | U32BE | 1 | |
| battery_voltage | 78 | U32BE | 0.001 | V |
| battery_current | 80 | U32BE | 0.001 | A |
| battery_power | 82 | U32BE | 1 | W |
| battery_temperature | 84 | U16 | 0.01 | deg C |
| charger_status | 85 | U16 | 1 | |
| invert_dc_current | 86 | U32BE | 0.001 | A |
| invert_dc_power | 88 | U32BE | 1 | W |
| charge_dc_current | 90 | U32BE | 0.001 | A |
| charge_dc_power | 92 | U32BE | 1 | W |
| charge_dc_power_percentage | 94 | U16 | 1 | % |
| ac1_frequency | 95 | U16 | 0.01 | Hz |
| ac1_voltage | 96 | U32BE | 0.001 | V |
| ac1_input_current | 98 | U32BE | 0.001 | A |
| ac1_input_power | 100 | U32BE | 1 | W |
| ac1_input_power_apparent | 102 | U32BE | 1 | VA |
| ac1_l1_voltage | 104 | U32BE | 0.001 | V |
| ac1_l2_current | 106 | U32BE | 0.001 | A |
| ac1_l2_voltage | 108 | U32BE | 0.001 | V |
| ac1_l1_current | 110 | U32BE | 0.001 | A |
| ac1_voltage_qualified | 112 | U16 | 1 | |
| ac1_frequency_qualified | 113 | U16 | 1 | |
| ac1_qualified_duration | 114 | U32BE | 1 | s |
| load_ac_voltage | 120 | U32BE | 0.001 | V |
| load_ac_l1_voltage | 122 | U32BE | 0.001 | V |
| load_ac_l2_voltage | 124 | U32BE | 0.001 | V |
| load_ac_l1_current | 126 | U32BE | 0.001 | A |
| load_ac_l2_current | 128 | U32BE | 0.001 | A |
| load_ac_current | 130 | U32BE | 0.001 | A |
| load_ac_power | 132 | U32BE | 1 | W |
| load_ac_power_apparent | 136 | U32BE | 1 | VA |
| load_ac_frequency | 138 | U16 | 0.01 | Hz |
| energy_from_battery_this_hour | 144 | U32BE | 0.001 | kWh |
| battery_discharge_active_this_hour | 146 | U32BE | 1 | s |
| energy_from_battery_today | 148 | U32BE | 0.001 | kWh |
| battery_discharge_active_today | 150 | U32BE | 1 | s |
| energy_from_battery_this_week | 152 | U32BE | 0.001 | kWh |
| battery_discharge_active_this_week | 154 | U32BE | 1 | s |
| energy_from_battery_this_month | 156 | U32BE | 0.001 | kWh |
| battery_discharge_active_this_month | 158 | U32BE | 1 | s |
| energy_from_battery_this_year | 160 | U32BE | 0.001 | kWh |
| battery_discharge_active_this_year | 162 | U32BE | 1 | s |
| energy_from_battery_lifetime | 164 | U32BE | 0.001 | kWh |
| battery_discharge_active_lifetime | 166 | U32BE | 1 | s |
| energy_to_battery_this_hour | 168 | U32BE | 0.001 | kWh |
| battery_charge_active_this_hour | 170 | U32BE | 1 | s |
| energy_to_battery_today | 172 | U32BE | 0.001 | kWh |
| battery_charge_active_today | 174 | U32BE | 1 | s |
| energy_to_battery_this_week | 176 | U32BE | 0.001 | kWh |
| battery_charge_active_this_week | 178 | U32BE | 1 | s |
| energy_to_battery_this_month | 180 | U32BE | 0.001 | kWh |
| battery_charge_active_this_month | 182 | U32BE | 1 | s |
| energy_to_battery_this_year | 184 | U32BE | 0.001 | kWh |
| battery_charge_active_this_year | 186 | U32BE | 1 | s |
| energy_to_battery_lifetime | 188 | U32BE | 0.001 | kWh |
| battery_charge_active_lifetime | 190 | U32BE | 1 | s |
| ac1_input_energy_this_hour | 192 | U32BE | 0.001 | kWh |
| ac1_input_active_this_hour | 194 | U32BE | 1 | s |
| ac1_input_energy_today | 196 | U32BE | 0.001 | kWh |
| ac1_input_active_today | 198 | U32BE | 1 | s |
| ac1_input_energy_this_week | 200 | U32BE | 0.001 | kWh |
| ac1_input_active_this_week | 202 | U32BE | 1 | s |
| ac1_input_energy_this_month | 204 | U32BE | 0.001 | kWh |
| ac1_input_active_this_month | 206 | U32BE | 1 | s |
| ac1_input_energy_this_year | 208 | U32BE | 0.001 | kWh |
| ac1_input_active_this_year | 210 | U32BE | 1 | s |
| ac1_input_energy_lifetime | 212 | U32BE | 0.001 | kWh |
| ac1_input_active_lifetime | 214 | U32BE | 1 | s |
| load_output_energy_this_hour | 216 | U32BE | 0.001 | kWh |
| load_output_active_this_hour | 218 | U32BE | 1 | s |
| load_output_energy_today | 220 | U32BE | 0.001 | kWh |
| load_output_active_today | 222 | U32BE | 1 | s |
| load_output_energy_this_week | 224 | U32BE | 0.001 | kWh |
| load_output_active_this_week | 226 | U32BE | 1 | s |
| load_output_energy_this_month | 228 | U32BE | 0.001 | kWh |
| load_output_active_this_month | 230 | U32BE | 1 | s |
| load_output_energy_this_year | 232 | U32BE | 0.001 | kWh |
| load_output_active_this_year | 234 | U32BE | 1 | s |
| load_output_energy_lifetime | 236 | U32BE | 0.001 | kWh |
| load_output_active_lifetime | 238 | U32BE | 1 | s |
| nominal_battery_voltage | 254 | U32BE | 0.001 | V |
⚠ UNINTENDED OPERATION: The use of this product with Modbus communications requires expertise in the design, operation, and programming of the device. Only qualified persons should program, install, alter, and commission this product. When writing values to the device, you must ensure other persons are not working with the device. Failure to follow these instructions can result in death or serious injury, and/or equipment damage. — Starkest reads only; we never write a control register.
| wiring notes | The entire serial bus may behave unexpectedly if the master device cannot communicate with all the slave devices on the bus. |
| protocol notes | Modbus does not provide an error response when data written to a Modbus Register is out of range or invalid. To confirm that a Modbus Register is correctly written, you should read it back and compare it with the expected value. |
| model register | 0x0000 |
| serial register | 0x002B |
| firmware register | 0x001E |
| identification notes | Unique ID Number is available at register 0x0014. |
| doc revision | Revision A.4 |
| firmware applicability | Conext SW Device Modbus map applies to products: 865-2524, 865-2524-61, 865-4024, 865-4024-61 |
Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.
Device not here? Upload its manual and get a checked map back. It's free.
Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.