device library

SolarEdge SE6000 inverter

Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.

coherence-checked

Round-trips through a real Modbus stack with no overlapping addresses and a word-order-sensitive codec — the map is internally coherent and wire-decodable. Does NOT prove byte-order or scaling match a real device: the emulator is seeded from the map's own types, so a uniformly wrong byte-order still round-trips. Only hardware-verified confirms byte-order/scale on the wire.

pointaddress (0-based)typescaleunit
i_ac_voltageab40076U161V
i_ac_current40071U161
i_ac_power40083I161kW
i_ac_energy_wh40093U32BE1kWh
i_ac_frequency40085U161Hz
m_ac_pf40221I161
i_status40107U161
i_temp_sink40103I161
c_sunspec_id40000U32BE1
m_exported40226U32BE1
i_ac_currenta40072U161

The trust ladder

Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.

Device not here? Upload its manual and get a checked map back. It's free.

Want it confirmed against your own device? Order hardware verification. If it doesn't check out, you don't pay.

Building on a lot of devices? License the library — machine-readable maps, the firmware matrix, and API access.