Toshiba VF-AS3 drive

Register map(s) for this device, with a note of how far each has been checked. Addresses are 0-based, as on the wire. Scale and byte order are confirmed only at the hardware-verified rung.

coherence-checked

Round-trips through a real Modbus stack with no overlapping addresses and a word-order-sensitive codec — the map is internally coherent and wire-decodable. Does NOT prove byte-order or scaling match a real device: the emulator is seeded from the map's own types, so a uniformly wrong byte-order still round-trips. Only hardware-verified confirms byte-order/scale on the wire.

pointaddress (0-based)typescaleunit
Command mode selection3U161
Frequency setting mode selection 14U161
Setting of acceleration / deceleration time unit1305U161
Integrating wattmeter display unit selection1865U161
MODBUS continuous address2096U161
Number of motor pole pair for communication2134U161
Communication function reset2201U161
Device Name 149281U161
Device Name 249282U161
Device Name 349283U161
Device Name 449284U161
Device Name 549285U161
Device Name 649286U161
Device Name 749287U161
Device Name 849288U161
Device Name 949289U161
Device Name 1049290U161
Device Name 1149291U161
Device Name 1249292U161
Device Name 1349293U161
Device Name 1449294U161
Device Name 1549295U161
Device Name 1649296U161
Emb Eth. Communication error detection delay50694U160.1sec
Emb Eth. Communication error operation50695U161
Emb Eth. Preset speed at communication error50696U161
Emb Eth. Communication error detection50697U161
Emb Eth. IP setting mode50698U161
Emb Eth. IP address setting value 150699U161
Emb Eth. IP address setting value 250700U161
Emb Eth. IP address setting value 350701U161
Emb Eth. IP address setting value 450702U161
Emb Eth. Subnet mask setting value 150703U161
Emb Eth. Subnet mask setting value 250704U161
Emb Eth. Subnet mask setting value 350705U161
Emb Eth. Subnet mask setting value 450706U161
Emb Eth. Default gateway setting value 150707U161
Emb Eth. Default gateway setting value 250708U161
Emb Eth. Default gateway setting value 350709U161
Emb Eth. Default gateway setting value 450710U161
Emb Eth. MAC address monitor 150723U161
Emb Eth. MAC address monitor 250724U161
Emb Eth. MAC address monitor 350725U161
Emb Eth. MAC address monitor 450726U161
Emb Eth. MAC address monitor 550727U161
Emb Eth. MAC address monitor 650728U161
Emb Eth. IP address monitor 150729U161
Emb Eth. IP address monitor 250730U161
Emb Eth. IP address monitor 350731U161
Emb Eth. IP address monitor 450732U161
Emb Eth. Subnet mask monitor 150733U161
Emb Eth. Subnet mask monitor 250734U161
Emb Eth. Subnet mask monitor 350735U161
Emb Eth. Subnet mask monitor 450736U161
Emb Eth. Default gateway monitor 150737U161
Emb Eth. Default gateway monitor 250738U161
Emb Eth. Default gateway monitor 350739U161
Emb Eth. Default gateway monitor 450740U161
Emb Eth. Scanner input select 150753U161
Emb Eth. Scanner input select 250754U161
Emb Eth. Scanner input select 350755U161
Emb Eth. Scanner input select 450756U161
Emb Eth. Scanner input select 550757U161
Emb Eth. Scanner input select 650758U161
Emb Eth. Scanner input select 750759U161
Emb Eth. Scanner input select 850760U161
Emb Eth. Scanner output select 150769U161
Emb Eth. Scanner output select 250770U161
Emb Eth. Scanner output select 350771U161
Emb Eth. Scanner output select 450772U161
Emb Eth. Scanner output select 550773U161
Emb Eth. Scanner output select 650774U161
Emb Eth. Scanner output select 750775U161
Emb Eth. Scanner output select 850776U161
Emb Eth. I/O scan timeout detection time50790U160.1s
Emb Eth. Web server50792U161
Emb Eth. Web server reset50793U161
Emb Eth. Unit ID50794U161
Emb Eth. Command monitor50838U161
Emb Eth. Frequency command monitor50839U161
Emb Eth. Error monitor50840U161
Emb Eth. External error monitor50841U161
Communication command1 from embedded ethernet64054U161
Frequency command from embedded ethernet64055U160.01Hz
Communication command 2 from embedded ethernet64056U161
Torque command setting from embedded ethernet64064U160.01%
Terminal output data64080U161
Alarm code64657U161
Output frequency64768U160.01Hz
Inverter status 164769U161
Output current64771U160.01%
Input voltage (DC detection)64772U160.01% (V)
Output voltage64773U160.01% (V)
Input terminal status64774U161
Output terminal status64775U161
Speed feedback frequency (real time)64790I160.01Hz
Torque64792I160.01% (Nm)
Torque current64796U161
PID feedback value64802U160.01Hz
Motor overload factor64803U161
Inverter overload factor64804U161
Braking resistor overload factor64805U161
Motor load factor64806U161
Inverter load factor64807U161
Input power64809U160.01kW
Cumulative run time for monitor65044U161hour
Terminal RR input value65077U160.01%
Terminal RX input value65078I160.01%
Terminal II input value65079U160.01%
FM output monitor65088U161
AM output monitor65089U161

link settings as documented (unverified): TCP; unit ID 0; FC 03,06,16,23,43; Modbus TCP over Ethernet. Unit ID 0 or C670 value is used to access the inverter. Unit ID 255 is used for the I/O Scanner.

bench facts as documented (unverified)
connectorDual RJ45 shielded connector
wiring notesSupports Daisy chain topology and Star topology. Auto MDI-X and LLDP are supported.
max registers/read63
protocol notesWriting via function codes 06 and 16 writes to EEPROM, which has a lifespan of approximately 100,000 writes. Writing via function code 23 (I/O scanning) writes to RAM.
identification notesSupports Read Device Identification (0x2B) for Basic and Regular Device ID.
FC 43 device IDsupported
doc revisionE6582125②

⚠ disputed: output_power @ 64810 — disputed by Embedded Ethernet Function Manual E6582125, which states output_power is at 0xFD30 (64816). 64810 (0xFD2A) is an invalid/unused address.

field reports — community-sourced, unverified (checked 2026-06-11)
  • Siemens S7-1200 MB_CLIENT block may return error 8381 (Function code not supported) when attempting to read registers like FD01h (64769) if the Unit ID is set to 0. To resolve this, change the inverter's C670 parameter (Emb Eth. Unit ID) to 1 and set the PLC's MB_Unit_ID to 1. [source]
  • The VF-AS3 does not have parameters for communication numbers ending in A through F (e.g., 0xXXXA to 0xXXXF and 0xXXAX to 0xXXFX). Reading a block of registers that spans these non-existent ranges will result in a Modbus error unless parameter F830 (MODBUS continuous address) is enabled (set to 1), which allows the drive to skip these addresses. [source]
  • confirmed: comms defaults and function codes (03, 06, 16, 23, 43) — confirmed by Embedded Ethernet Function Manual E6582125
  • confirmed: Unit ID 0 or C670 value is used to access the inverter, and Unit ID 255 is used for the I/O Scanner — confirmed by Embedded Ethernet Function Manual E6582125
  • confirmed: Dual RJ45 shielded connector supporting Daisy chain and Star topologies, Auto MDI-X, and LLDP — confirmed by Embedded Ethernet Function Manual E6582125
  • confirmed: Writing via FC06 and FC16 writes to EEPROM (lifespan ~100,000 writes), while FC23 writes to RAM — confirmed by Embedded Ethernet Function Manual E6582125
  • confirmed: frequency_command @ 64055 (0xFA07) — confirmed by Embedded Ethernet Function Manual E6582125
  • confirmed: torque_command @ 64064 (0xFA40) — confirmed by Embedded Ethernet Function Manual E6582125
  • confirmed: alarm_code @ 64657 (0xFC91) — confirmed by Embedded Ethernet Function Manual E6582125
  • confirmed: output_frequency @ 64768 (0xFD00) — confirmed by Embedded Ethernet Function Manual E6582125

The trust ladder

Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.