Register map(s) for this device, each at the trust rung it earned. Addresses are 0-based as on the wire; word order and scaling are only confirmed at the hardware-verified rung.
Read + decoded cleanly over a real network vs an independent third-party Modbus test server (transport and framing; reads are remapped into the server's register window, so the map's own addresses are NOT exercised). Does NOT prove word order/scaling against the actual device.
| point | address (0-based) | type | scale | unit |
|---|---|---|---|---|
| flow_rate_on_screen | 600 | F32BE | 1 | |
| velocity_on_screen | 602 | F32BE | 1 | |
| delta_time_filtered | 604 | F32BE | 1 | |
| energy_btu_rate | 608 | F32BE | 1 | |
| temperature_1 | 610 | F32BE | 1 | |
| temperature_2 | 612 | F32BE | 1 | |
| delta_temperature | 614 | F32BE | 1 | |
| flow_rate_gpm | 800 | F32BE | 1 | |
| velocity_fps | 802 | F32BE | 1 | |
| energy_rate_kbtu | 804 | F32BE | 1 | |
| flow_rate_lpm | 1000 | F32BE | 1 | |
| velocity_mps | 1002 | F32BE | 1 | |
| energy_rate_kwh | 1004 | F32BE | 1 | |
| net_flow_totalizer_home_units | 2300 | F32BE | 1 | |
| positive_flow_totalizer_home_units | 2302 | F32BE | 1 | |
| negative_flow_totalizer_home_units | 2304 | F32BE | 1 | |
| gross_flow_totalizer_home_units | 2306 | F32BE | 1 | |
| energy_btu_net_total_home_units | 2316 | F32BE | 1 | |
| energy_btu_positive_total_home_units | 2318 | F32BE | 1 | |
| energy_btu_negative_total_home_units | 2320 | F32BE | 1 | |
| energy_btu_gross_total_home_units | 2322 | F32BE | 1 | |
| net_flow_totalizer_gal | 2400 | F32BE | 1 | |
| positive_flow_totalizer_gal | 2402 | F32BE | 1 | |
| negative_flow_totalizer_gal | 2404 | F32BE | 1 | |
| gross_flow_totalizer_gal | 2406 | F32BE | 1 | |
| energy_btu_net_total_kbtu | 2416 | F32BE | 1 | |
| energy_btu_positive_total_kbtu | 2418 | F32BE | 1 | |
| energy_btu_negative_total_kbtu | 2420 | F32BE | 1 | |
| energy_btu_gross_total_kbtu | 2422 | F32BE | 1 | |
| net_flow_totalizer_liters | 2500 | F32BE | 1 | |
| positive_flow_totalizer_liters | 2502 | F32BE | 1 | |
| negative_flow_totalizer_liters | 2504 | F32BE | 1 | |
| gross_flow_totalizer_liters | 2506 | F32BE | 1 | |
| energy_net_total_kwh | 2516 | F32BE | 1 | |
| energy_positive_total_kwh | 2518 | F32BE | 1 | |
| energy_negative_total_kwh | 2520 | F32BE | 1 | |
| energy_gross_total_kwh | 2522 | F32BE | 1 | |
| signal_strength | 5500 | U16 | 1 | count |
| current_output_1_ma | 5601 | F32BE | 1 | mA |
| current_output_2_ma | 5604 | F32BE | 1 | mA |
| current_output_3_ma | 5607 | F32BE | 1 | mA |
| terminals | TB700 terminals 3 (RS485+) and 4 (RS485-) |
| A/B polarity | automatically detects which lines are A and B... automatically corrects for the RS485 negative and positive connections being swapped |
| termination | Built-in resistor that can be selected through the communication setting (60.4 Ohms x 2) |
| connector | TB700 |
| shield/ground | Typically, one end of the shield drain is connected to a clean ground to dissipate EMI |
| wiring notes | Up to 126 transmitters to be placed on a single three-wire cable up to 4000 feet. |
| protocol notes | When a USB programming cable is connected, the RS485 and frequency outputs are disabled. |
| serial register | 47129 |
| firmware register | 47193 |
| identification notes | Part Number: 47065, Calibration Date: 47257, Date Code: 47321 |
| doc revision | TTM-UM-03073-EN-01 (August 2019) |
Each rung states what it proved and what it did not. Gray until proven; green is earned by hardware only.
Have a device that isn't here? Upload its register map — generation is free, and the connector earns its rung by being proven, not claimed.
Need it proven on your own device? Hardware verification — if it doesn't verify, you don't pay.
Building a platform? License the verified library — machine-readable maps, firmware matrix, API access.